Brivis Evaporative Cooler Parts Guide: Contour, Profiler and Promina Parts Explained

Brivis Evaporative Cooler Askoll Pump - #B017245

This guide covers the Brivis evaporative cooler parts that most often need replacing in Contour, Profiler, Promina and AD series coolers, the symptoms that point to each one, and how to match the right part to your cooler. You can browse the full range in Brivis evaporative cooler parts.

Find your Brivis model first

Brivis models are shown on the cooler’s compliance label, for example Contour L41, Profiler P63 or AD45. Filter pads in particular are matched to model ranges, and some parts changed between generations, so note the model and any part number on the old part before ordering.

Water system parts

Brivis cooler pump

Dry pads and warm air usually mean a pump or water supply problem. Many Brivis coolers use the Askoll pump (B017245), which sits in the Askoll pump base (B008961). See Brivis cooler pumps and our evaporative cooler pump guide.

Solenoid valves, float valve and water sensors

Brivis coolers take water in through a 240V solenoid valve: the 3/4″ solenoid valve (B0081140) or the Elbi barbed solenoid valve (81019245). Models with a mechanical float use the Philmac float valve (B000414), while electronic models use water sensors such as the Contour water level sensor (B018066) and the Contour L0 water sensor (B015571). Water reaches the pads through the water distribution pipe assembly (B008913). See our float valve and solenoid guide.

Snorkel drain system

Many Brivis coolers drain the tank through a snorkel assembly moved by a damper motor. If the tank won’t drain or won’t hold water, check the damper motor assembly (B023973) and the snorkel, such as the Contour L1 snorkel (B018062), Contour L0 snorkel (B015888) or BA-F snorkel (B019431).

Brivis Contour pads and filter pads

Brivis pads are sold in packs of four matched to model ranges, for example Contour L41-L45, Contour L31-L36 / P43-P46, Contour L21-L26 / P23-P36, Profiler/Promina P63-P76 and AD11 to AD36. Replace them when they’re crusted with scale, crumbling or smelly. See Brivis filter pads and our evaporative cooler pads guide.

Motors and fan parts

If airflow is weak, noisy or has stopped, the motor, fan or a related part may need replacing. We stock Brivis motors including the S4 750W motor (81064588), S3 750W motor, S3 315W motor and S4+ 1000W motor, along with the 11 blade fan assembly, fan collet, fan speed sensor, 28 vane stator and motor mounting grommets.

Control boxes and wall controllers

Brivis control boxes include the N-E6 main control box with switch, the N-E6 control box without switch, the N-E1 control box and the TEK467 control box, plus the 516 network module and 526 add-on module. Wall controllers include the NC-6 Networker and the Brivis manual wall controller. Our wall controller replacement guide helps you work out whether the controller, loom or control box has failed.

Quick fault finder

  • Warm air, dry pads: Askoll pump, solenoid, float valve or water sensor.
  • Tank won’t hold water or won’t drain: snorkel or damper motor.
  • Overflowing: float valve or solenoid stuck open.
  • Weak or noisy airflow: motor, fan, collet, stator or speed sensor.
  • Controller blank or fault showing: wall controller, loom or control box.

Safety first

Brivis coolers are usually installed on the roof and wired to 240V. Replacing motors, pumps, solenoids and control boxes should be done by a qualified technician or licensed electrician, with the power isolated first.

Frequently asked questions

How do I know which Brivis pads I need?

Find your model on the cooler’s compliance label (for example Contour L41) and choose the pack whose model list includes it.

Why won’t my Brivis cooler drain?

On coolers with a snorkel drain, a failed damper motor or a damaged snorkel is a common cause.

Do you sell genuine Brivis evaporative cooler parts?

Yes. Each product page lists the Brivis part number so you can match it to your old part.

What’s the difference between the N-E6 control boxes?

We stock the N-E6 main control box with an isolation switch and without one. Match the version to your existing box.

Need help with Brivis evaporative cooler parts? Contact HotnCool with your model number and the part number on the old part, and we’ll help you find the right one.