How to Operate Brivis Evaporative Cooling: Networker and Manual Wall Control

Brivis Networker Thermostat NC6

Brivis evaporative cooling is controlled either by a Networker digital controller or a simple Manual Wall Control. This guide explains how to operate a Brivis evaporative cooler with each one, how to get the best cooling, and what to check if it won’t start.

Need a replacement? Shop Brivis evaporative cooler controllers or browse all Brivis spare parts, in stock and dispatched fast Australia-wide.

Which Brivis controller do you have?

How to operate Brivis evaporative cooling with a Networker

  1. Start with the Networker turned off.
  2. Press MODE until Cooler is selected, then turn the Networker on.
  3. Press AUTO to choose Auto or Manual operation.
  4. Auto: set your Comfort Level with the rotary dial. The cooler switches the pump and fan on and off to hold that level.
  5. Manual: you control the fan speed and turn the pump (cooling water) on or off yourself. The Networker remembers your last settings.

Expect a delay at start-up. The pads must be soaked before the fan starts, so it can take up to about 8 minutes before cool air arrives, especially if the tank was empty.

How to operate Brivis evaporative cooling with a Manual Wall Control

  1. Turn the Cool switch on. This starts the pump and wets the pads.
  2. Wait 5 to 10 minutes for the pads to soak.
  3. Turn the Fan switch on.
  4. Set the airflow with the Fan Speed dial.

To run fan only (no cooling water), leave the Cool switch off and turn on just the Fan.

Tips for the best cooling

  • Open windows or doors. Evaporative cooling needs air to escape. Open a window or door in the rooms you are cooling, on the side away from the wind.
  • Humid days: evaporative cooling works less well. Run the fan without the pump (fan only) for air movement.
  • Check the pads. Pads should be evenly wet when running. Dry patches usually mean a blocked water distributor or a failing pump. Worn pads reduce cooling: see Brivis evaporative cooler pads.
  • Shut-down delay is normal. After switching off, the cooler may run a drain or tank wash for a while.

Brivis cooler won’t start? Quick checks

  • Is the power isolation switch on at the cooler?
  • Is the controller set correctly (Cooler mode, Auto or Manual, or Cool and Fan switches on)?
  • Is the Networker in a time delay or timer mode?
  • Has the cooler’s fuse or circuit breaker in the meter box tripped?
  • Is the water supply turned on?

If the Networker shows an error code, see our Brivis evaporative cooler fault codes guide. If the controller screen is blank or unresponsive, our Brivis controller guide explains how to tell a faulty controller from a cable or control box fault.

Frequently asked questions

Why does my Brivis cooler take so long to blow cold air?

The pads must be fully soaked before the fan starts. On a Networker this can take up to about 8 minutes, longer if the tank has just been drained.

What is the difference between Auto and Manual on a Brivis Networker?

Auto holds the Comfort Level you set by switching the pump and fan for you. Manual lets you choose the fan speed and whether the pump runs.

Can I run my Brivis cooler as a fan only?

Yes. On a Manual Wall Control, turn on only the Fan switch. On a Networker in Manual, turn the pump off and the fan keeps running.

Which Brivis cooler models use these controls?

Networker controls are used on Brivis Contour and other networked coolers. Find parts for your model on our Brivis cooler parts by model page.

Based on Brivis evaporative cooler owner’s manual instructions. Always follow the manual for your specific model.